News

Home >  News > Industry trends > 

DC 9733 Blower Fan for Small Spaces

Sep 23, 2025


The DC 9733 Blower Fan is a high-performance cooling solution specifically engineered to address the unique challenges of small-space environments, such as compact industrial enclosures, medical device housings, automotive electronic modules, and miniaturized server racks. Its 9733form factor97mm in width, 97mm in height, and 33mm in depthbalances a larger airflow-generating design with a low-profile structure, making it suitable for spaces where height or depth is limited but cooling demand is high (e.g., a 1U servers internal cavity or a portable medical ultrasound machine).

Small spaces present distinct cooling challenges: limited air volume, restricted airflow paths, and a higher risk of hotspots due to component density. The 9733 blower fan addresses these issues through three key design attributes. First, its centrifugal airflow design delivers highly directional, high-pressure air streamsunlike axial fans, which spread air broadly and struggle to penetrate tight gaps. At a typical operating voltage of 12V or 24V, the fan operates at 3,500 to 5,000 RPM, generating airflow ranging from 18 to 28 CFM and static pressure of 40 to 65 Pascals (Pa). This combination allows it to push air through narrow ducts, around dense component clusters (e.g., a stack of 2.5-inch SSDs in a mini-server), or through thin dust filterscritical for small enclosures where airflow resistance is often high.

Second, the fans compact depth (33mm) enables installation in spaces where larger blowers or axial fans would not fit. For example, in a 1U server (which has a height of just 44.45mm), the 9733 blower can be mounted horizontally above the CPU heat sink, with its outlet directed toward the servers front ventsmaximizing cooling without exceeding the chassis height limit. In automotive applications (e.g., a cars ADAS (Advanced Driver-Assistance Systems) control unit, which is often housed in a small dashboard compartment), the fans narrow profile allows it to fit alongside sensors and wiring harnesses while still cooling the units processor and power management components.

Third, the 9733 blowers design prioritizes noise reduction and reliabilityessential for small spaces where fans are often close to users or sensitive equipment. Its BLDC motor operates with minimal vibration, and its backward-curved impeller blades reduce turbulence, resulting in a noise level of 3545 decibels (dB) at full speedquieter than many smaller high-RPM fans (e.g., 40mm server fans at 5565 dB). This makes it suitable for medical devices like portable oxygen concentrators, where noise can cause patient discomfort, or office-based mini-servers, where loud fans would disrupt the workspace.

Real-world applications highlight the fans effectiveness in small spaces: in a compact 2U network switch with 24 Ethernet ports and a 1.2GHz ARM-based controller, the 9733 blower maintained internal temperatures at 3848°C (vs. 5565°C with a smaller 60mm fan), preventing overheating and ensuring consistent data transfer speeds. In a medical grade blood glucose monitor with a small LCD screen and a microprocessor, the fans directional airflow kept the processor temperature at 3242°C during continuous use, ensuring accurate readings and extending the devices lifespan. Additionally, the fans high MTBF (Mean Time Between Failures) of 70,00080,000 hours makes it a reliable choice for 24/7 small-space applications, where downtime is costly or critical.

Turbine-Structured CPU Fans for Powerful Heat Dissipation

Aug 06, 2025

Computer Case Fan 4028 Compact Powerhouse in Cooling Technology

Apr 09, 2025

Small-Size DC Blower Fans for Compact Electronics

Jun 25, 2025

Connect With Our Experts Now

If you have any suggestions and comments on our products and services, please fill in the following table

0755-21031801 / 13823749690

Message