Server Fan 8038 Airflow Tests for Performance

Nov 11, 2025


Conducting rigorous airflow tests on a server fan like the 8038 (80mm x 80mm x 38mm) is not a mere formality; it is an absolute necessity to validate its performance claims and ensure it is fit for its intended purpose in a mission-critical environment. For IT managers, system integrators, and data center engineers, these test results are the ultimate arbiter of a fan's capability. Performance testing for such a fan is a multi-dimensional process conducted in a controlled environment, typically using an wind tunnel compliant with standards like AMCA (Air Movement and Control Association) or ISO, and it focuses on three core metrics: airflow volume (CFM), static pressure (mmHO), and acoustic noise (dBA).

The most fundamental test is the CFM rating, which measures the volume of air the fan can move per minute with no restriction (free air delivery). However, this number alone is almost meaningless for a server application, as fans never operate without restriction. This is where the static pressure test becomes critical. The fan is subjected to increasing levels of resistance (simulating heatsinks, dust filters, and packed drive bays), and its ability to maintain airflow is measured. The resulting data is plotted on a PQ (Pressure-Volume) curve. A high-quality 8038 fan will have a steep curve, indicating it can maintain strong airflow even against high backpressure, which is exactly what is required inside a dense server chassis.

Simultaneously, the fan's acoustic output is measured at various points on this PQ curve. The sound power level (measured in dBA) is recorded to create a performance-to-noise profile. A fan might move 100 CFM at a given pressure, but if it requires 55 dBA to do so, it is far less efficient than a fan that achieves the same result at 45 dBA. Furthermore, the quality of the sound is analyzed; a fan with poorly balanced blades or inferior bearings will produce an unpleasant tonal noise or bearing whine, even if its overall dBA level is acceptable. For an 8038 fan, tests also verify its performance across its entire PWM speed range and at elevated ambient temperatures, ensuring it will not fail under duress. These comprehensive tests separate true performance workhorses from mere spec-sheet champions.

Liquid cooled CPU Fan for Overclocking

Jul 08, 2025

How to Solve the Problem of a Loud and Buzzing CPU Fan

Nov 20, 2024

12V 14025 Computer Case Fan

Nov 05, 2025

Connect With Our Experts Now

If you have any suggestions and comments on our products and services, please fill in the following table

0755-21031801 / 13823749690

Message